Generic Mido M036.407 Gold Watch Crown And Tube 6.6mm

$7.00
You Saved

Discount

Quantity Discount (%) Price
1 - 2 $7.00
3 - 4 5 % $6.65
5 - 9 8 % $6.44
10+ 12 % $6.16
x

Product Description

This is a generic gold crown and tube set designed for the Mido M036.407 series, featuring a crown diameter of 6.6mm and a height of 3.36mm. The set includes both the crown and its matching case tube, providing a comprehensive solution for repairing worn or damaged winding systems while maintaining the original two-tone aesthetic.

Key Features & Functions

  • Complete crown and tube set
  • Gold finish for classic two-tone aesthetic
  • Crown dimensions: 6.6mm diameter × 3.36mm height
  • Screw-down design for water resistance
  • Cost-effective alternative to genuine Mido parts

Usage Instructions

Proper Crown Operation (Screw-Down Type):

  1. Unscrew: Turn the crown counter-clockwise until it releases from the case tube threads

  2. Position 0 (screwed down): Normal running position, maximum water resistance

  3. Position I (unscrewed, not pulled): Manual winding (turn clockwise)

  4. Position II (unscrewed, pulled to first stop): Quick-set date correction

  5. Position III (unscrewed, pulled to second stop): Time setting

Important Reminders:

  • Always screw the crown down fully after adjustments to maintain water resistance

  • Never pull the crown without unscrewing first – this can damage the setting mechanism

  • If the crown feels resistant when turning, do not force it

Installation Instructions

Tools Required:

  • Case back opener

  • Pin vise or spring bar tool

  • Non-metallic tweezers

  • Small screwdriver (for movement release)

  • Silicone grease (for gasket)

  • Crown tube press tool

  • Loctite 222 (low-strength threadlocker)

Step-by-Step Installation:

Step 1: Remove the Old Crown and Tube

  • Open the case back and locate the crown release mechanism (press the button near the stem)

  • Gently pull the crown and stem out of the movement

  • Unscrew the old crown from the stem using a pin vise

  • For tube removal: Use a tube press tool to push the old tube out from inside the case

Step 2: Clean the Case

  • Clean the tube hole and crown seating area using isopropyl alcohol

  • Remove all old adhesive and debris

Step 3: Install the New Tube

  • Apply a small amount of Loctite 222 to the outside of the new tube

  • Insert the tube from the outside of the case

  • Press firmly until the tube sits flush with the case surface

  • Allow adhesive to cure (10-15 minutes)

Step 4: Prepare the New Crown

  • Apply silicone grease to the crown‘s rubber gasket

  • Screw the new gold crown onto the winding stem (clockwise, snug fit only)

Step 5: Reinstall and Test

  • Insert the stem with new crown into the movement until it clicks

  • Test all crown positions (winding, date setting, time setting)

  • Professional water resistance testing is strongly recommended

Important Notes

  • Complete set – Includes both crown and tube; install both for proper sealing
  • Thread compatibility – Verify that the thread size matches your watch‘s winding stem
  • Water resistance testing – Professional testing is mandatory after installation
  • Gasket replacement – Use the new gasket provided; never reuse old gaskets
  • Professional installation recommended – Improper installation can compromise water resistance

Repair Guide

Common Symptoms Indicating Crown/Tube Replacement is Needed:

Symptom Possible Cause
Crown spins without tightening Stripped threads on crown or tube
Crown pulls out without unscrewing Worn screw-down mechanism
Difficulty winding Worn crown or stem threads
Water enters watch after exposure Failed crown gasket or damaged tube
Visible corrosion on crown Oxidation from moisture exposure

When Replacement is Necessary:

  • Stripped or damaged threads on the crown or tube

  • Cracked or hardened gasket

  • Visible corrosion or physical damage

  • Crown no longer screws down smoothly

Preventive Maintenance:

  • Replace gaskets every 3-5 years during regular service

  • Always screw down the crown after adjustments

  • Rinse the watch with fresh water after saltwater exposure before operating the crown

  • Avoid over-tightening the crown

Frequently Asked Questions

Q1: What models is this crown compatible with?

A: This crown is specifically designed for the Mido M036.407 series. Always verify your original crown dimensions (6.6mm diameter) and thread type before purchasing.

Q2: Does the crown need to be screwed down for water resistance?

A: Yes. The original watch is designed with a screw-down crown system for water resistance. When the crown is in the unscrewed position, the watch is not water-resistant. Always screw the crown down tightly after making adjustments.

Q3: Can I install this crown myself?

A: If you have experience with watch repair and the proper tools (case opener, pin vise, tube press, etc.), installation is possible. However, for users without experience, professional installation is strongly recommended. Improper installation can compromise water resistance and damage the movement.

Q4: How do I maintain the gold finish?

A: Clean the crown periodically with a soft cloth and mild soapy water. Avoid harsh chemicals (perfumes, chlorine, cleaning agents) that may damage the gold finish. Do not use abrasive polishes as they may wear through the coating.

Why Choose SOFLY Watch Parts?

  • Fast worldwide shipping within 3 business days.

  • Competitive pricing on Seiko/Hattori calibers.

  • 3,000+ watch movements and parts in stock.

  • Trusted by watchmakers worldwide.

  • Personalized sourcing support via [email protected] or WhatsApp +86 18620212114.