Generic TAG Heuer Gold Crown Screw Down 4.4*3.4mm

$25.00
You Saved

Discount

Quantity Discount (%) Price
1 - 2 $25.00
3 - 4 5 % $23.75
5 - 9 8 % $23.00
10+ 12 % $22.00
x

Product Description

This is a generic gold screw-down crown designed for select TAG Heuer watch models, measuring 4.4 × 3.4 mm with M0.90 (Tap 10) threading. Featuring a gold plated finish, this crown is designed to replace worn, stripped, or damaged original crowns, restoring the watch‘s winding, time-setting, and water sealing functions.

As an economical alternative to the original crown, it is ideal for watch restoration or professional servicing projects.

Technical Specifications

Specification Description
Compatible Brand TAG Heuer
Dimensions 4.4 × 3.4 mm
Thread Specification M0.90 (Tap 10)
Color Gold
Material Steel + gold plating
Type Screw-down crown
Function Manual winding, time setting, date adjustment, screw-down water resistance

Usage Instructions

  • Normal Operation:Unscrew crown counter-clockwise, pull to first position for date setting (if supported), second position for time setting.

  • After Adjustment:Push crown back to original position and tighten clockwise to ensure water resistance. The screw-down crown provides double water resistance protection with an additional seal that becomes watertight when screwed down.

  • Manual Winding:With crown unscrewed, rotate clockwise for manual winding.

  • Thread Alignment Tip:Push in and turn counter-clockwise until you hear a “click” – threads are aligned, then tighten clockwise.

  • Precautions:Always screw down the crown after adjustment to prevent moisture ingress; the screw-down crown also prevents accidental function changes.

Installation Instructions

1. Remove Movement Open the case back and carefully remove the movement.
2. Remove Old Crown Press the movement setting lever while pulling out the old crown. If the crown is stuck, use specialized tools to extract it carefully.
3. Clean Winding Stem Clean the winding stem threads to remove old oil and debris.
4. Inspect Stem/Case Tube Check the winding stem threads; if the crown fails to lock, the case tube threads may be worn – replace both together if necessary.
5. Install New Crown Screw the new crown onto the winding stem – ensure threads align without cross-threading.
6. Test Functions Test crown pull/push functions for smooth operation and distinct position detents.
7. Water Test Perform a professional water resistance test after installation.

Important Note: The crown is a critical component of the water resistance system – improper installation may allow moisture to enter and damage the movement. It is recommended to replace the case tube and sealing gasket (purchased separately) together with the crown. TAG Heuer recommends crown replacement be performed by authorized service centers. Professional installation by a watchmaker is strongly recommended.

Important Notes

  • Size Confirmation This crown measures 4.4 × 3.4 mm with M0.90 (Tap 10) threading – Tap 10 is a common thread specification for TAG Heuer and other brands. Verify original crown dimensions before purchase.
  • Thread Alignment Ensure threads align correctly during installation – cross-threading will damage the crown or stem threads.
  • Gasket Inspection Inspect the crown gasket before installation; replacement is recommended (purchased separately). Service kits including crown and case back gaskets are available for models like the TAG Heuer Aquaracer.
  • Simultaneous Replacement If the crown fails to lock properly, the case tube threads may be worn – replace the case tube together with the crown.
  • Torque Control Tighten until the crown sits flush with the case – do not over-tighten to prevent thread damage.

Maintenance & Guide

  • Inspection Period Check crown locking feel and gasket condition every 2-3 years.
  • Stripped Thread Treatment If crown feels rough or fails to lock, threads may be worn – replace the crown (and case tube).
  • Cleaning Wipe crown surface with a soft cloth; avoid chemical solvents.
  • Gasket Replacement Replace the crown gasket when replacing the crown.
  • Diagnosis For accurate failure diagnosis, a professional watchmaker should inspect the crown and case tube threads under magnification.
  • Replacement Criteria Replace if crown shows stripped threads, fails to lock, plating wear, or thread damage.
  • Water Damage Treatment If water enters due to an unscrewed crown, immediate service is required.

FAQ

Q1: Is this crown compatible with my TAG Heuer watch?

A;This crown measures 4.4 × 3.4 mm with M0.90 (Tap 10) threading. Tap 10 (0.90mm thread diameter) is a common crown thread specification for TAG Heuer watches, suitable for TAG Heuer models using this specification. Verify your original crown dimensions and thread size before purchase.

Q2: Can I install this crown myself?

A;Crown replacement requires movement removal and careful handling. If you have watch repair experience and proper tools, it is possible. However, professional installation by a watchmaker is strongly recommended to avoid cross-threading or compromising water resistance. TAG Heuer recommends crown replacement be performed by authorized service centers.

Q3: Why does my crown feel rough when screwing down?

A;Roughness when tightening often indicates dirty or damaged threads, or a worn gasket. Stop immediately, clean the threads, and inspect for damage. If the problem persists, the crown or case tube threads may be worn and require replacement together.

Why Choose SOFLY Watch Parts?

  • Fast worldwide shipping within 3 business days.

  • Competitive pricing on Seiko/Hattori calibers.

  • 3,000+ watch movements and parts in stock.

  • Trusted by watchmakers worldwide.

  • Personalized sourcing support via [email protected] or WhatsApp +86 18620212114.

Our Popular Items